Installation, Operation and Service ManualMU155N Series - 120V 60HzIce and Water DispensersCool Ideas For Ice Management209091R00801 Church Lane • PO
9Cleaning bin before use1. Wipe storage area with Solution A.2. Rinse thoroughly with clear, potable water.3. Wipe with Solution B to sanitize.Periodi
Dispense chute cover removal 1. Remove top cover.2. Push chute cover up vertically to slip off holding tab.3. After clearing tab, pull chute cover for
ServiceDisassembly instructions for service requirements only – NOT required forany cleaning procedureDispense wheel motor removal (Fig. 3)1. Remove d
BlkBlkCOUNTERCLOCKWISE ROTATIONCOUNTERCLOCKWISE ROTATIONRedYelRedRedSWITCH NO. 1SWITCH NO. 2IM_#2IM_#1AutoFill Timer24 VoltsR1BluT-STATBIN22Red339618
13SymptomIce does not dispense.• Auger motor does not run• Wheel motor does not runIce does not dispense.• Auger motor runs• Wheel motor runs• Gate do
Reference # Description Part #1 Label, “Follett” 5024382 Top cover (includes label and magnet) 5029053 Drain pan (includes magnet) 5029034 Grille, dr
Dispense assembly side view(right-hand unit shown)Reference # Description Part #1 Gate, dispense 5024552 Linkage pin, gate/solenoid 5024563 Pin, quick
162Reference # Description Part #1 Auger, LH unit (black, stamped with “1”) 502491Not shown Auger, RH unit (gray, stamped with “2”) 5024922 Plate, aug
17Reference # Description Part #Auger motor/drive assembly, vertical (includes all items below) 5029531 Motor, vertical auger (includes gearbox and ca
Reference # Description Part #1Transformer, 24V 5020582 Relay, dispense 5018263 Relay, auto fill 5018264 Timer, auto fill (automatic fill units) 50247
Cool Ideas For Ice Management209091R004/02801 Church Lane • PO Box D, Easton, PA 18044(610) 252-7301 • FAX (610) 250-0696 • www.follettice.com®
Table of contentsWelcome to Follett. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Before you begin. . . . . . .
Welcome to FollettFollett ice and water dispensers enjoy a well-deserved reputation for excellent performance, long-term reliabilityand outstanding af
PlumbingDispenser 3/4" PVC slip joint for hopper drain3/4" PVC pipe nipple for beverage drain pan3/8 ID red line tubing for water inNote: Dr
5Junction boxJunction boxField wiring diagram is intended to aid electrician or technician in understanding how equipment works.IMPORTANTL1L2GNDElectr
InstallationInstalling MU155N dispenser in counter1. Check that dispenser location meets all requirements in this manual and cut counter as shown. 2.
Installing remote icemaker (automatic load units only)1. Position icemaker in desired location. 2. Push one end of ice transport tube(s) through hole(
To start up and operate dispenser1. Follow detailed cleaning instructions in service manual before operating dispenser.2. For manual load units, rem