Follett 400 Series Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
Specifications
4
Electrical
Model number Full load amps Max. fuse size
MC400 series icemaker 115/60/1 11.0 amps 20 amps
Ambient specifications
Air temperature 100˚F/38˚C max. 50˚F/10˚C min. (best performance below 80˚F/27˚C)
Water temperature 90˚F/32˚C max. 40˚F/4˚C min. (best performance below 70˚F/21˚C)
Water pressure 70 P.S.I. max.(482kPA) 10 P.S.I min. (89kPA)
Plumbing
Your new icemaker is equipped with a drain line to simplify draining the evaporator and float reservoir. The tube
labeled “float/evap drain” is for SERVICE USE ONLY and must NOT be connected to the icemaker drain.
Water line sizes Make up water (inlet to float) 1/4" min.
Condenser (water-cooled only) 3/8" min.
Drain line sizes Icemaker drain 3/4" min.
Condenser (water-cooled only) 3/8" min.
Slope to drain 1/4" per foot (6mm per 30.4cm run) 1/2" min.
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
Follett recommends installation of a Follett water filter system (part# 00130229) in icemaker inlet water line
Field Wiring: countertop dispensers with Satellite-fill icemakers
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
Vista de pagina 3
1 2 3 4 5 6 7 8 9 ... 19 20

Comentarios a estos manuales

Sin comentarios